Photometrics Driver Download

Multi Channel Photometric Converter

  1. Photometrics Driver Download
  2. Photometrics Driver Download Software
  3. Photometrics Drivers
  4. Photometrics Driver Download Windows 7
  5. Photometrics Software
  6. Photometrics Driver Download Windows 10
  7. Photometrics Driver Download Pc
  1. Driver Calculator; Design Service. Select from the list of product categories below to download the relevant IES and LDT files. Type: Downloads.
  2. OpenCVgrabber - Supports numerous USB cameras and frame grabbers (those using a DirectShow or WDM class driver). (Windows) PCOCamera - Supports all pco.sdk based cameras (pco.edge, pco.panda and others) Photometrics - A.k.a. PVCAM; PICAM - Princeton Instruments cameras using the PICam interface Piper - Stanford Photonics cameras.

Installing a Biometric Driver.; 2 minutes to read; t; D; n; In this article. Vendors can provide an INF file to install a WBDI driver. The following is a list of guidelines for biometric device installation. Technical Downloads Important information when downloading all BIM Models or IES Files: Clicking on the box below immediately starts the downloading process of ALL BIM Models or IES files. The zip files can be up to 600MB in size and can take several minutes for the download to appear. Photometric Considerations in Design of Displays for the Older Driver 920615 Several aspects of visual functioning deteriorate as part of the normal aging process. These include a reduction in luminance and color contrast sensitivity, an increase in sensitivity to glare, a reduction in visual accommodation capacity, and a reduction in the.

The C4000 converter is a multi channel controller capable of operating all optek photometric sensors. The C4000 converter allows for easy programming and operation, and can supply up to four real time configurable 4-20 mA output values correlated to any units of measure. The C4000 offers configurable relay alarms, can record and download process data, and can operate up to four sensors simultaneously.

    Used For

  • For UV, VIS, NIR Absorption sensors
  • Color scales:
    • APHA / HAZEN / Pt/Co color
    • AOCS (Method Cc 13b-45) color
    • ASTM (D1500) color
    • EBC color
    • ASBC color
    • Gardner (ASTM D1544) color
    • ICUMSA color
    • KLETT color
    • Reference Base Unit (RBU, color)
    • Saybolt (ASTM D 156, D 6045) color
  • Turbidity scales:
    • CU (concentration units)
    • ppm (DE)
    • FTU
    • NTU
    • FAU
    • EBC

The Control 4000 photometric converter is designed for optek ultraviolet (UV), visible (VIS), near-infrared (NIR) absorption based and scattered light based sensors. The graphic display can show absorbance, transmittance and concentration in real-time and in any unit of measure such as CU, OD, %-Tr., ppm (DE), EBC, FTU, g/L and many others.

Display Modes

  • 1 - 4 simultaneously displayed values (configurable)
  • Numeric with bar graph and alarm setting
  • Trendline

Remote Control

  • Parameter set (e. g. range)
  • Zero
  • Hold

Software Tools

  • 8 parameter sets (incl. range, alarm, display, etc.)
  • 16 linearization tables (max. 11 points)
  • 8 offset and slope sets
  • Auto zero (local or remotely activated)
  • Factory zero (scattered light sensors only)
  • Password protection (3 levels and none)
  • Memory (non-volatile) retains all configurations and logged data

Photometrics Driver Download

Benefits
4 channel photometric measurement converter and 2 signal inputs
Connect up to 4 photometric sensors and 2 analogue devices (e.g., pressure / temperature compensation in gas measurement)
Menu based software in serveral languages including linearization curve options
Easy configuration of the converter for individual applications

Photometrics Driver Download Software

Can be installed in hazardous areas saving additional installation costs
Graphics display for up to 4 real time measurements
Free editable measurement formats and multiple data display and output capabilities
Optional Profibus®PA and FOUNDATION™Fieldbus connectivity
Easy implementation of data communication into Bus-Environment
Photometrics
C4000
Housing

19'-version for mounting in control cabinets 3 U / 42 HP

dimensions:W 213.0 mm (8.39 in.) H 128.4 mm (5.06 in.) D 230.0 mm (9.05 in.)

material:stainless steel / polyester / silicone / glass / diverse plastics

protection:front IP40 / rear IP20 (mains supply secured against accidental touching)

Display

LCD graphic display black on white (240 x 128 pixel), LED background illuminated

Operation

18-button keyboard

System clock

accuracy approx. 1 minute/month (battery life approx. 15 years)

LED

1 LED (green):power on

1 LED (red-flashing):system failure

3 LEDs (yellow):alarm I, II, III

Data logger

4 parallel measuring values

(ring buffer with approx. 25,000 data points x 4)

(interval: 1/second - 1/hour)

Sensor-inputs

1 - 4 for optek photometric sensors

Sensor-inputs
(explosion proof)

optional:1 - 4 for optek photometric sensors (intrinsic safe)

mA-inputs

optional:

2 x 4 - 20 mA (functionally galvanically isolated)

accuracy:< 0.5 %

resolution:< 0.05 %

load:< 200 Ohm

Remote-inputs

optional:7 x 24 V (19 ... 29 V DC),
typically 6.0 mA for remote range setting, remote zero, remote hold

Profibus® PA interface

optional:

Profibus® PA profile, version 3.01, amendment 2

FOUNDATION™ Fieldbus interface

optional:

FOUNDATION™ Fieldbus H1 (IEC 61158-2)

Sensor lamp-outputs

1 or 2 lamp supply for optek photometric sensors

4.5 ... 8.5 V DC

mA-outputs

2 or 4 x 0/4 - 20 mA (NAMUR)

(functionally galvanically isolated)

accuracy:< 0.5 %

resolution:< 0.05 %

load:< 600 Ohm

Relay-outputs

3 independent software-configurable relay contacts

0 - 50 V AC, 0 - 75 V DC, 0 - 2 A

for alarm or status feedback

initiation delay configurable: 0 - 999 sec.

Failsafe-output

1 SPDT contact to alarm in case of lamp or system failure (active)

0 - 50 V AC, 0 - 75 V DC, 0 - 2 A

Serial communication

RS232 bi-directional interface on front panel (with software package optek PC-transfer)

upload / download of configuration, download of data logger content

Cable lengths
(sensor)

2, 3, 5, 10, 15, 20, 30 ... 100 m

(7, 10, 16, 33, 49, 66, 98 ... 328 ft)

cable length > 100 m on request up to 1,000 m (3,280 ft)

sensors: AS56 / AS16: max: 50 m

sensors: ASD: 2, 3, 5 or 10 m (7, 10, 16 or 33 ft.)

Power supply

115 / 230 V AC, selectable (93.5 - 132 / 187 - 264 V AC, 47 - 64 Hz) or 24 V AC / DC (AC: 20.4 - 26.4 V AC, 47 - 64 Hz; DC: 20.4 - 28.8 V DC)

power consumption:< 50 VA

Ambient conditions

temperature during operation (no direct sunlight):

converter: -10 - 55 °C (14 - 131 °F)

with optional stainless steel housing S19-42 (IP65): -20 - 45 °C ( -4 - 113 °F)

with optional plastic housing B19-42 (IP66): -10 - 40 °C (14 - 104 °F) (C4000 only)

with optional Ex D housing (IP65): -20 - 40 °C ( -4 - 104 °F) (C4000 only)

temperature during transport (no direct sunlight): -20 - 70 °C ( -4 - 158 °F)

Software languages

English, German, French, Spanish, Dutch, Portuguese, Russian

Data given are subject to changes without prior notice.

Photometrics Drivers

SensorC4000 Configurations
12344101 4121 4151 41614201 4221 4251 42614202 4222 4252 4262 4422 4452 4462
AF16 (AS16)---
AF16 (AS16)AF16 (AS16)----
AF16 (AS16)AF26 or AF45 or TF16-----
AF26----
AF26AF26 or AF45 or TF16-----
AF45----
AF45AF45 or TF16-----
AF46------
TF16----
TF16TF16-----
ASD12 or ASD25---
ASD12 or ASD25ASD12 or ASD25---
ASD12 or ASD25ASD12 or ASD25ASD12 or ASD25----
ASD12 or ASD25ASD12 or ASD25ASD12 or ASD25ASD12 or ASD25---
C4000 Configurations4101420142024121422142224422
1Detector inputs (optek)1221224
2Power supply 115/230 or 24 V
3Remote-IN: (Zero, Range, Hold)---
4Relay-outputs3333333
Failsafe-relay (active)
5Lamp output (optek)1121122
6mA-outputs (0/4 - 20 mA)2242244
7mA-inputs (4 - 20 mA)---2222
pH-probe- (with C8000 only)
Conductivity (optek ACF)- (with C8000 only)
Ex-proof (optional)

Photometrics Driver Download Windows 7

PROFIBUS® PA

  • Fulfills application profile for process automation (version 3.01)
  • Cyclic:
    • 4 measuring outputs, each with 4x limit and status
    • Status of all 4 relays
    • 2 measuring inputs
  • Acyclic:
    • Zero, Hold, Product change, Monitors, Error codes
  • GSD, EDD file and DTM for FDT interface provided
  • Interface to profibus DP segment using a segment coupler

FOUNDATION™ Fieldbus

  • Fulfills FOUNDATION™ Fieldbus H1 (IEC 61158-2)
  • Registered function blocks: 1xRB, 8xAI(s), 4xDI(s), 2xAO(s)
  • H1 Profile class: 31P, 32L
  • H1 Device class: basic, link master
  • 4 Measuring outputs with status (C8000 8 measuring outputs with status)
  • 4 Relays with status (C8000 1 Relay with status)
  • 2 Measuring inputs (only C4000)
  • With optek specific resource block parameter: Zero, Hold, Product change
  • Device description (DD) and capabilities files provided
Download
C4000 Configurations
8PROFIBUS® PA4151425142524452
FOUNDATION™ Fieldbus4161426142624462
1Detector inputs (optek)1224
2Power supply 115/230 or 24 V
3Remote-IN: (Zero, Range, Hold)----
4Relay-outputs3333
Failsafe-relay (active)
5Lamp output (optek)1122
6mA-outputs (0/4 - 20 mA)2244
7mA-inputs (4 - 20 mA)----
pH-probe- (with C8000 only)
Conductivity (optek ACF)- (with C8000 only)
Ex-proof (optional)

Front panel Mounting Kit for series C4000, C8000, HazeControl

PN: 1200-3321-0001-00

Wall mount housing B19-42 for 1 converter C4000, HazeControl or for 2 converters X56

PN: 1200-3321-0002-00

Wall mount housing S19-42 for 1 converter C4000, C8000, HazeControl or for 2 converters X56

PN: 1200-3321-0003-00

Photometrics Software

C4000 - C8000 Product Information

Photometrics Driver Download Windows 10

Visit our documentation page to view a complete list of translated documents.

Call Us:
Germany
+49-(0)201-63409-0
United States
+1-262-437-3600
Singapore
+65-6562-8292
China
+86-21-28986326

Photometrics Driver Download Pc

Select from the list of product categories below to download the relevant IES and LDT files.

TypeDownloads
BollardsDownload IES and LDT files now >
Colour Change Excl. StripDownload IES and ldt files now >
Commercial LightingDownload IES and ldt files now >
DownlightsDownload IES and ldt files now >
Emergency LightingDownload IES and ldt files now >
Ground LightsDownload IES and ldt files now >
Retail LightsDownload IES and ldt files now >
Spike LightsDownload IES and ldt files now >
Strip LightsDownload IES and ldt files now >
Universal LightsDownload IES and ldt files now >
Wall LightsDownload IES and ldt files now >